- Fan Selection Software FS10 is a powerful selection tool designed for engineers and fan professionals. FS10 provides an intuitive user interface for making both quick and advanced fan selections based on specific system requirements.
- Armed with a 5-year warranty, we are an industrial fan and blower manufacturer for professional engineers looking to improve facility air movement.
- Cook Fan Selection Software
- Loren Cook Fan Selection Software
- Cook Fan Selection Software
- Loren Cook Fan Selection Software
Replacement Parts. When you need parts to keep your fan up and running, you can rest assured that Aerovent has you covered. Whether you need common replacement parts or a backup supply of spare parts for process critical applications, our team can assist you in selecting the right part for your fan – regardless of the manufacturer. Team TEAMS is an engineering design tool allowing application-based selection of grilles, registers, diffusers, VAV terminals, and fan coils for commercial HVAC systems. The TEAMS installation includes all of the Titus air distribution selection software suite of products: TEAMS 9 VAV, Fan Coil, Blower Coil, Air Handler and Chilled Beam Selection. Clarage’s Fan Selection Software provides quick and accurate application tools for configuring custom fans. The Selector Program provides performance operating data such as flow and pressure, horse power and sound data. Sound data includes: inlet and outlet sound power levels in eight octave bands, LwA, sound pressure in dBA and sones. This calculated drive loss is added to the required fan power to obtain the actual operating power required. The Medium range is the default and is suitable for most applications, however the Low range may be more appropriate for low speed applications and the High range for higher speed applications or where a more conservative value is desired.
Your covid-19 partner
We are proud to have the opportunity to help in the fight against COVID-19. Winning eleven for ppsspp. We will get through this together.
A complete range of standard products & fully customized ventilation systems.
Understanding the needs of our customers is second nature to us.
Supporting a wide range of industries and customers across the globe.
Offering the most maintenance friendly products on the market.
WHO WE ARE
As a leading designer and manufacturer of high quality industrial air moving equipment, Aerovent sets the industry standard. Our broad range of technologies and expertise allow us to provide the most innovative and efficient air moving and ventilation products on the market. Since 1932, we have been supplying fans to industries covering most Fortune 500 companies, as well as small and medium sized companies that demand high quality products with a wide range of features. We have completed thousands of successful installations worldwide and have a proven track record for tackling the most technically complex and unique applications.
Unmatched Quality
Our experienced team combines a unique skill set and craftsmanship to build the best fans possible. By utilizing the highest quality materials and the most advanced equipment and manufacturing techniques, our product quality is unsurpassed in the air moving industry. We operate eight manufacturing facilities across the U.S. and strive for the highest quality at every step of the manufacturing process – fabrication, welding, machining, painting, assembly, testing and crating. We offer a wide choice of construction materials and accessories for specialty applications including composite, stainless steel, aluminum, hot-dip galvanized steel, abrasion and spark resistant alloys, along with numerous protective coatings.
Replacement Parts

When you need parts to keep your fan up and running, you can rest assured that Aerovent has you covered. Whether you need common replacement parts or a backup supply of spare parts for process critical applications, our team can assist you in selecting the right part for your fan – regardless of the manufacturer. Not sure which part you need? No problem, contact our Parts Department at parts@aerovent.com or by phone at 763-551-7500.
Common replacement parts include:
- Motors & Drives
- Wheels & Impellers
- Belts & Sheaves
- Shafts & Bearings
- Companion Flanges
Field services
Having the peace of mind that your fan is installed and operating properly prior to start-up is crucial. That is why Aerovent offers a wide range of start-up services and precision checks, including inlet and wheel operational clearances, torque verification, shaft alignment, balance and vibration testing. As part of our standard start-up services, Aerovent field personnel will conduct a variety of inspection checks to ensure the fan is ready for start-up — all the way from the foundation bolts to the lubrication of the fan.
(Requires Javascript activation)
COOK Restaurant Exhaust Ventilator provides maximum performance and durability in kitchen hood exhaust applications.
- VCR unit top cap assembly is designed to provide weather protection for the motor and drive components while maintaining easy tool free access for inspection and maintenance.
- Standard lifting lugs, located under the top cap, provide for safe, fast and efficient lifting of the unit to a rooftop.
- One piece fan base, which includes a high-efficiency inlet venturi and continuously welded curb cap corners, insures weathertight conditions. One piece spun aluminum leak-free baffle is designed to provide smooth, turbulent-free airflow. Wheels are centrifugal type featuring non-overloading, backward-inclined blades and a tapered inlet shroud.
- Optional Wall Mounting Flange is available up to size 245.
- Accurate performance is assured through compliance with the AMCA Certified Ratings Program. All units are licensed to bear the AMCA Certified Ratings Seal for Air and Sound Performance
- Construction Features include
- Removable Top Cap
- Regreasable Pillowblock Bearings In Cast Iron Housing
- Standard NEMA 3 Wiring Box
- Motor Cooling Tube
- Stainless Steel Quick Release Fasteners
- Lifting Lugs
- Heat Shield
- Aluminum Base with Welded Corners
- Aluminum Wheel
- Electronially communtated motors available
See the Downloads tab for specifications, submittals, and FanDrafter files
See alsoSRSH: Tamper Resistant Downblast Centrifugal Exhaust Ventilators
See alsoAC: Centrifugal Roof and Wall Exhauster Ventilators
VCRD
VCR
Options & Accessories
Downloads
LOREN COOK COMPANY certifies that the VCRD, VCRD-EC, VCRD-HP, VCRD-XP, VCRDEC-HP ,VCRDEC-XP shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
Type VCRD, VCRD-HP, VCRD-XP are furnished standard with UL 762 and CUL 762 listings (Power Ventilator for Restaurant Exhaust Appliances/YZHW) when furnished with factory supplied motor.
All sizes are available with express service. Read more
Upblast Centrifugal
Restaurant Exhaust
Ventilator
Roof Mounted
Direct Drive
VCR available in 6 direct drive sizes.
Cook Fan Selection Software
- Impeller Size:10 - 18 in
- Flow: 399 - 4,391 CFM
- SP: 0 - 1.5 in

Description:Fan shall be a spun aluminum, roof mounted, direct driven, upblast (standard, high pressure, or extended pressure) centrifugal exhaust ventilator
Certifications:Fan shall be manufactured at an ISO 9001 certified facility. Fan shall be listed by Underwriters Laboratories (UL 762) and UL listed for Canada (Power Ventilator for Restaurant Exhaust Appliances). Fan shall bear the AMCA certified ratings seal for sound and air performance.
Construction:The fan shall be of bolted and welded construction utilizing corrosion resistant fasteners. The spun aluminum structural components shall be constructed of minimum 16 gauge marine alloy aluminum, bolted to a rigid aluminum support structure. The aluminum base shall have a one piece inlet spinning and continuously welded curb cap corners for maximum leak protection. The windband shall have a rolled bead for added strength. A two piece top cap shall have stainless steel quick release latches to provide access into the motor compartment without the use of tools. An external wiring compartment with integral conduit chase shall be provided into the motor compartment to facilitate wiring connections. The motor shall be enclosed in a weather-tight compartment, separated from the exhaust airstream. Unit shall bear an engraved aluminum nameplate. Nameplate shall indicate design CFM and static pressure. Unit shall be shipped in ISTA certified transit tested packaging.
Wheel: Wheel shall be centrifugal backward inclined, constructed of 100 percent aluminum, including a precision machined cast aluminum hub. Wheel inlet shall overlap an aerodynamic aluminum inlet cone to provide maximum performance and efficiency. Wheel shall be balanced in accordance with AMCA Standard 204-05, Balance Quality and Vibration Levels for Fans.
Motor: Motor shall be NEMA design B with a minimum of class B insulation rated for continuous duty and furnished at the specified voltage, phase and enclosure.
Product: Fan shall be manufactured by LOREN COOK COMPANY of Springfield, Missouri.
LOREN COOK COMPANY certifies that the VCR, VCR-HP and VCR-XP shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
Type VCR, VCR-HP, VCR-XP are furnished standard with UL 762 and CUL 762 listings (Power Ventilator for Restaurant Exhaust Appliances/YZHW) when furnished with factory supplied motor.
Upblast Centrifugal
Restaurant Exhaust
Ventilator
Roof Mounted
Belt Drive
Loren Cook Fan Selection Software
VCR available in 17 belt drive sizes.- Impeller Size:10 - 49 in
- Flow: 279 - 28,806 CFM
- SP: 0 - 1.5 in
Description:Fan shall be a spun aluminum, roof mounted, belt driven, upblast (standard, high pressure, or extended pressure) centrifugal exhaust ventilator
Certifications:Fan shall be manufactured at an ISO 9001 certified facility. Fan shall be listed by Underwriters Laboratories (UL 762) and UL listed for Canada (Power Ventilator for Restaurant Exhaust Appliances). Fan shall bear the AMCA certified ratings seal for sound and air performance.
Construction: The fan shall be of bolted and welded construction utilizing corrosion resistant fasteners. The spun aluminum structural components shall be constructed of minimum 16 gauge marine alloy aluminum, bolted to a rigid aluminum support structure. The aluminum base shall have a one piece inlet spinning and continuously welded curb cap corners for maximum leak protection. The windband shall have a rolled bead for added strength. A two piece top cap shall have stainless steel quick release latches to provide access into the motor compartment without the use of tools. An external wiring compartment with integral conduit chase shall be provided into the motor compartment to facilitate wiring connections. The motor, bearings and drives shall be mounted on a minimum 14 gauge steel power assembly. These components shall be enclosed in a weather-tight compartment, separated from the exhaust airstream. A one inch thick, three pound density foil backed heat shield shall be utilized to protect the motor and drive components from excessive heat. Lifting lugs shall be provided to help prevent damage from improper lifting. Unit shall bear an engraved aluminum nameplate. Nameplate shall indicate design CFM, static pressure, and maximum fan RPM. Unit shall be shipped in ISTA certified transit tested packaging.
Wheel: Wheel shall be centrifugal backward inclined, constructed of 100 percent aluminum, including a precision machined cast aluminum hub. Wheel inlet shall overlap an aerodynamic aluminum inlet cone to provide maximum performance and efficiency. Wheel shall be balanced in accordance with AMCA Standard 204-05, Balance Quality and Vibration Levels for Fans.
Motor: Motor shall be Nema design B with class B insulation rated for continuous duty and furnished at the specified voltage, phase and enclosure.
Bearings: Bearings shall be designed and individually tested specifically for use in air handling applications. Construction shall be heavy duty regreasable ball type in a cast iron pillow block housing selected for a minimum L50 life in excess of 200,000 hours at maximum cataloged operating speed.
Belts and Drives: Belts shall be oil and heat resistant, static conducting. Drives shall be precision machined cast iron type, keyed and securely attached to the wheel and motor shafts. Drives shall be sized for 150 percent of the installed motor horsepower. The variable pitch motor drive must be factory set to the specified fan RPM.
Product: Fan shall be manufactured by LOREN COOK COMPANY of Springfield, Missouri
Motors
- Direct Drive
- All direct drive motors are standard single phase 115-volt.
- Size 100 are either shaded pole or permanent split capacitor type motors.
- Sizes 120 through 180 are either permanent split capacitor (1075, 1300, or 1550 rpm motors) or split phase (1140 or 1725 rpm motors).
- FSC can only be used on either shaded pole or permanent split capacitor type motors.
- Optional motors:
- Two speed, single-phase open motors supplied as 1725 RPM motors are 1725/1140, or 1140 RPM motors are 1140/860.
- Explosion proof motors are available for some units, contact factory for details.
- These optional motors cannot use an FSC.
- Three-phase standard efficiency and three-phase Variable Frequency Drive (VFD) compatible motors are available, consult factory for details.
- Two speed, single-phase open motors supplied as 1725 RPM motors are 1725/1140, or 1140 RPM motors are 1140/860.
- EC Motor
- Electronically Commutated (EC) Motors offer significantly improved energy efficiency and controllability over traditional fractional HP motors. The EC motor is offered in 1/4, 1/2 and 3/4 HP sizes for 120v, single phase applications and has an adjustable speed range of 500 to 1725 rpm. Two control options are available for each motor. The 'Motor Mounted Speed Control' version includes an integral potentiometer mounted on the exterior of the motor for adjusting the motor speed. A screwdriver is used for adjustment. The 'External Signal Speed Control' version requires a 0-10 VDC control signal to adjust the speed of the motor as well as a 24 VAC power source to operate the motor control circuit (a 24v transformer is included with the fan to power the motor control circuit). The motor will operate from 2-10 VDC and will turn off below when the control signal is below 1.9 VDC.
- Belt Drive
- Single-phase motors:
- Open drip motors from 1/6 to 1-1/2 HP.
- Two-speed, motors in 1725/1140RPM, from 1/6 to 1 HP.
- TEFC and Class 1, Group D, explosion proof motors from 1/4 to 1 HP.
- Three-phase motors:
- Three-phase ODP motors from 1/4 to 10 HP.
- Two-speed, two winding motors in 1725/1140 RPM, from 1/3 to 5 HP.
- TEFC and Class 1, Group D, explosion proof motors from 1/4 to 10 HP.
- Variable Frequency Drive (VFD) compatible motors are available, contact factory for details.
- All single-phase and three-phase, single speed, open drip motors listed in performance tables are shipped factory installed.
- Single-phase motors:
Automatic Belt Tensioner: The automatic belt tensioner maintains constant tension on the drive belt which offers two distinct benefits. It reduces startup and maintenance costs by continuously tensioning the belt throughout it’s life and also increases belt life by reducing slippage. Engineering studies indicate properly tensioned belts can operate at 15° to 20° F cooler internal temperature than poorly tensioned belts. A drive belt industry rule of thumb is that every 18° F increase in internal temperature will reduce belt life by 50%. The automatic belt tensioner will easily double belt life compared to installations where belt tension is not properly maintained. Cook’s spun aluminum fans have stainless steel quick release latches on the topcap, providing tool free access to the automatic belt tensioner and motor compartment. The drive belt can be replaced in moments (by almost anyone) without the special skills and tools normally needed to achieve proper belt tension. Too much belt tension can reduce the life of both the fan and motor bearings. The COOK automatic belt tensioner will assure proper belt tension throughout the life of the fan; maximizing bearing life and fan reliability.
Available on sizes 100 - 540.
Roof Curb:
Standard Construction Features:18 gauge galvanized steel (RCG) or .080 aluminum (RCA), 1-1/2”, 3 lbs. density thermal and acoustical insulation, Continuously welded corners, Wood nailer. Options: No wood nailer (deduct 1-1/2” for actual height), 13-1/2” tall construction.
Vented Extension constructed of galvanized steel, is used to increase the discharge height of the fan. Vents in the extension allow the interior ductwork to dissipate heat.
Extended Lube Lines provide a quick and convenient way to lubricate the bearings while the fan is operating.
Tie downs offer locations for field attachment of the fan to the roof deck or supporting structure. The tie down points help protect against high windloads.
The hinged base is a factory welded sub-base, hinge and locking hasp that provides a secure and stable means of access to the inlet and interior ductwork for cleaning and inspection. Galvanized aircraft cable is installed on the hinged base to support the fan in an open position. Available on sizes 100 through 300, consult factory on larger sizes.
Cook Fan Selection Software
The hinged base kit is a field installed option which provides a lockable, hinged connection between the fan and curb. This allows easy access to the wheel and inlet of the fan as well as the interior ductwork. The kit includes two hinge plates, two latch plates, hinge bolts, aircraft cable and clamps. Available on sizes 100 through 300, consult factory on larger sizes.
Grease Trough provides for collection of grease from a VCR unit. The lid is removable for cleaning. The grease trough is shipped loose for field mounting. To provide for more thorough periodic cleaning, the grease trough should be mounted to the unit for easy removal.
Grease Terminator 2 is a grease-capture and containment system.
Optional Coatings
Lorenized® is an electrostatically applied, baked polyester powder coating. Each component shall be subject to a five stage environmentally friendly wash system, followed by a minimum 2 mil thick baked powder finish. Coating must exceed 1,000 hour salt spray under ASTM B117 test method.
- COOK Epoxy Powder is an electrostatically applied, baked epoxy powder coating. Final coating thickness is 2.5 - 3.5 mils. For outdoor applications an optional UV resistant topcoat is available to prevent cosmetic chalking of the coating.
- COOK Phenolic Epoxy Powder is an electrostatically applied, baked phenolic epoxy powder coating. Final coating thickness is 2 - 4 mils. For outdoor applications an optional UV resistant topcoat is required to prevent deterioration of the coating.
- Cook Easy Clean Powder is an electrostatically applied, baked modified epoxy silicone powder producing a high temperature 'non-stick' coating. Final coating thickness is 1.3 - 1.7 mils.
- Air Dry Phenolic (Heresite VR-504) is a conventional spray applied phenolic resin coating. Final coating thickness is 4 - 6 mils. For outdoor applications an optional UV resistant topcoat (Heresite UC-5500) is required to prevent deterioration of the coating.
Refer to the corrosion resistance guide in the Compute-A-Fan software for a listing of the coatings above and their resistance to a variety of chemicals. Additional special coatings are available.
Control
- Fan Speed Control: a variable speed controller which can offer excellent energy conservation and lower sound levels when 100 percent of a direct drive fan operating capacity is not required. The FSC employs solid state circuitry for long-life and dependability. The FSC is available only on 115V and 230V shaded pole or permanent split capacitor direct drive motors and is not available on 1140 RPM and 1725 RPM motors. The FSC is normally shipped loose for field installation. Optional pre-wiring is available. 5 AMP or 10 AMP
- Fan Speed Control for EC Motors: External Speed Control for the Cook EC Motor allows the fan speed to be adjusted remotely via an easy to read dial. The controller allows for adjustment from 20-100% of the fan speed. The controller works with the external signal version of the Cook EC Motor and requires 24 VDC power for operation.
- Pressure control for EC Motors Constant pressure controller for the Cook EC Motor is for applications where the fan is intended to maintain a near constant pressure in a system such as dryer vents. The pressure controller reads the pressure in a duct system via the provided pressure transducer and automatically adjusts the fan rpm to maintain a preset value. The controller works with the external signal version of the Cook EC Motor and is shipped loose for field installation.